LIGO PRO User Guide: Difference between revisions
| [checked revision] | [checked revision] |
change content |
|||
| (8 intermediate revisions by the same user not shown) | |||
| Line 169: | Line 169: | ||
== Installation == | == Installation == | ||
=== Selecting the location to install sensor === | |||
* Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank. | * Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank. | ||
| Line 187: | Line 185: | ||
</div> | </div> | ||
=== Drilling the hole on fuel tank === | |||
* Drill out the central bore by bimetal core drill ø38 mm | * Drill out the central bore by bimetal core drill ø38 mm | ||
| Line 224: | Line 222: | ||
</div> | </div> | ||
=== Measuaring the tank depth and cutting sensor'measuring probe === | |||
<div style="text-align:center;"> | <div style="text-align:center;"> | ||
| Line 242: | Line 240: | ||
== Configuration == | == Configuration == | ||
=== Installing software and connecting configuration tool === | === On mobile platform === | ||
Connecting the sensor to LIGO mobile configurator | |||
<div style="text-align:center;"> | |||
[[File:LIGO-PRO-mobile-connect.png|frameless|600px]] | |||
<div style="font-style:italic; color:#555;">Figure 9. Connecting the sensor to the LIGO mobile configurator</div> | |||
</div> | |||
Configuring and managing the appropriate settings for the LiGO device sensor is essential to ensure its proper, stable, and accurate operation. It also allows for continuous monitoring of the device's operational status, potential failures (whether caused by the sensor itself or external factors), and overall lifespan. | |||
<div style="text-align:center;"> | |||
[[File:LIGO-PRO-mobile-ui.png|frameless|444px]] | |||
<div style="font-style:italic; color:#555;">Figure 10. Device's management, setting up and configuration software interface</div> | |||
</div> | |||
=== On PC Device === | |||
==== Installing software and connecting configuration tool ==== | |||
'''Preparation:''' | '''Preparation:''' | ||
| Line 257: | Line 272: | ||
12-24VDC | 12-24VDC | ||
=== Download and install software. Downloading and installing softwares === | ==== Download and install software. Downloading and installing softwares ==== | ||
==== Installing USB to RS232 driver ==== | ===== Installing USB to RS232 driver ===== | ||
* Installing driver for USB to RS232 cable | * Installing driver for USB to RS232 cable | ||
| Line 269: | Line 284: | ||
</div> | </div> | ||
==== Installing sensor software configuration ==== | ===== Installing sensor software configuration ===== | ||
* Visit our website: [ | * Visit our website: [http://sojielectronics.com/support/download/ http://sojielectronics.com/support/download/] and download setup file "Setup Utility Program " | ||
<div style="text-align:center;"> | <div style="text-align:center;"> | ||
| Line 345: | Line 360: | ||
'''Enable AutoClib feature:''' Sensor automatically calibrates Min, Max levels after cutting. User does not need to reconfigure after cutting. | '''Enable AutoClib feature:''' Sensor automatically calibrates Min, Max levels after cutting. User does not need to reconfigure after cutting. | ||
==== Min/Max Calibration ==== | ===== Min/Max Calibration ===== | ||
'''a) Set Empty level''' | '''a) Set Empty level''' | ||
| Line 400: | Line 415: | ||
<div style="text-align:center;"> | <div style="text-align:center;"> | ||
[[File: | [[File:RS232-RS485.jpg|frameless|756x756px]] | ||
<div style="font-style:italic; color:#555;">Figure 18. Wiring diagram of RS232 and RS485 output signals</div> | <div style="font-style:italic; color:#555;">Figure 18. Wiring diagram of RS232 and RS485 output signals</div> | ||
</div> | </div> | ||
| Line 470: | Line 485: | ||
</div> | </div> | ||
=== Quick installation without PC === | ==== Quick installation without PC ==== | ||
This method is only applicable to configure Min and Max level. | This method is only applicable to configure Min and Max level. | ||
==== Preparation before setting up ==== | ===== Preparation before setting up ===== | ||
* The sensor's auto-recognisation mode needs to be turned on by checking the "Enable AutoCalib Feature" box. | * The sensor's auto-recognisation mode needs to be turned on by checking the "Enable AutoCalib Feature" box. | ||
| Line 485: | Line 500: | ||
* External devices such as GPS tracking or Dataloger… must have the software integrated with the configurator. The configuration is performed directly on the device. | * External devices such as GPS tracking or Dataloger… must have the software integrated with the configurator. The configuration is performed directly on the device. | ||
==== Automatically setting up and configuring the sensor after cutting ==== | ===== Automatically setting up and configuring the sensor after cutting ===== | ||
* After measuring and cutting sensor, remove iron filings and clean burrs between the tubes, then follow steps below: | * After measuring and cutting sensor, remove iron filings and clean burrs between the tubes, then follow steps below: | ||
| Line 505: | Line 520: | ||
- In case of improper operation and the sensor cannot recognise properly the actual Min, Max level, user should reconfigure using a PC. | - In case of improper operation and the sensor cannot recognise properly the actual Min, Max level, user should reconfigure using a PC. | ||
==== Connecting multiple sensors together ==== | |||
''(Only applicable to RS232 and RS485)'' | |||
In some situations, there are oil tanks with specific dimensions, interconnected oil tanks, or oil tanks that are either too long or too large. Using just one sensor to measure the accurate fuel level inside these oil tanks may not be feasible. Hence, there is a need to connect two or more sensors together through a data processor called SUM-DATA. | |||
<div style="text-align:center;"> | |||
[[File:LIGO-PRO-multi-sensor-tank.png|frameless|728px]] | |||
<div style="font-style:italic; color:#555;">Figure 26. Oil tank with particular dimensions connecting multiple sensors together</div> | |||
</div> | |||
Connection diagram of the processor SUM-DATA for multiple sensors: | |||
<div style="text-align:center;"> | |||
[[File:LIGO-PRO-sumdata-2sensors.png|frameless|648px]] | |||
<div style="font-style:italic; color:#555;">Figure 27: Connecting two sensors by 01 processor SUM-DATA</div> | |||
</div> | |||
<div style="text-align:center;"> | |||
[[File:LIGO-PRO-sumdata-multi.png|frameless|707px]] | |||
<div style="font-style:italic; color:#555;">Figure 28: Connecting multiple sensors together by multiple processors SUM-DATA</div> | |||
</div> | |||
== Operation == | == Operation == | ||
Latest revision as of 07:34, 7 July 2026
Safety Information
| ℹ️ NOTICE — Installer Qualifications and Safety |
|---|
|
Product Overview
LIGO Fuel level sensor is produced and developed by SOJI Electronics Join Stock Company. The device is designed to measure the level of liquid fuels and other non-conductive liquids in vehicle's tanks and stationary fuel storages, applicable in different fields. The measured values will be t transformed into output signal in the form of: Analog, Frequency, RS232, RS485… and transmitted to a connected external device
Under particular conditions, the device can reach a high accuracy up to 99.5%. At present, on the market there are several lines of sensor using different technologies to measure fuel level such as: magnetically operated switches (reed switches), ultrasound wave (ultrasonic sensor), capacitive sensing (capacitive sensor). Among these ones, capacitive sensing technology is considered to have highest accuracy and greatest lifespan.
Package Contents
Apendix A
List of equipment for fuel level sensors installation
| STT | Descriptions | Qty |
|---|---|---|
| 1 | Bimetal core drill ø38 mm | 1 |
| 2 | Core drill shank | 1 |
| 3 | Metal drill ø7 mm & ø4 mm | 1 |
| 4 | Hacksaw | 1 |
| 5 | T Spanner 8mm Single Sided | 1 |
| 6 | Tap M5 with holder | 1 |
| 7 | Snap-seal for bolt/self-tapping screw | 1 |
| 8 | Laptop | 1 |
| 9 | DC power supply unit 12V-24V or battery 12V | 1 |
| 10 | Measuring container | 1 |
| 11 | Fuel | 1 |
| 12 | Gauging container | 1 |
| 19 | USB to RS232 cable | 1 |
| 20 | Tape mesaure | 1 |
Apendix B
Sensor LIGO SP and all the accessories
Error creating thumbnail: Unable to save thumbnail to destination
| STT | Description | Qty |
|---|---|---|
| 1 | LIGO Fuel Level Sensor. Standard lengths: 700, 1000, 1500mm (for other customized lengths, please contact the manufacturer) | 01 |
| 2 | 7m cable | 01 |
| 3 | Gasoline resistant rubber gasket | 01 |
| 4 | Oil filter | 01 |
| 5 | Anti-vibration spring | 01 |
| 6 | Fuse 2A | 01 |
| 7 | Sealing cord | 02 |
| 8 | Rivet and screw M5x20mm | 04 |
| 9 | Self-drilling screw M4.8x32mm | 04 |
Specifications
Technical specifications of the LIGO-SP product
| Parameter | AF | RS232 | RS485 |
|---|---|---|---|
| Standard length (L),mm | 700, 1000, 1500...up to 6000 mm | ||
| Measuring error, % | ± 0.5 % | ||
| Output signal | Analog (0…9V), Frequency (500… 2000Hz). | RS232 | RS485 |
| Baud rate, bit/sec | 9600 | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | |
| Power supply (DC input voltage, V) | 15-37 | 12-37 | 12-37 |
| Maximum power consumption, mA | 20 | ||
| Waterproof standard (Ingress protection rating, IP) | IP67 | ||
| Operating temperature, °C | -40...+85 | ||
| Maximum allowed humidity level,% | 100 | ||
| Resolution, bit | 12 | ||
| Digital reading range corresponding to the minimum level measurement value | Analog (0...8V); Frequency (500...1500 Hz) | 0 | 0 |
| Digital reading range corresponding to the maximum level measurement value | Analog (1...9V); Frequency (1000...2000 Hz) | 4095 | 4095 |
| Average sampling period, (s) | 0...255 | ||
| Message interval, (s) | Continuous | 1...60 | 1...60 |
| Absolute error in temperature measurement within the entire temperature measuring range, °С | ±2 | ||
| Average service life, (years)) | 8 | ||
Technical specifications of the LIGO-SP PRO product
- LIGO-SP PRO product is designed for devices having wide input voltage (7-75V), the voltage of the internal sensing printed circuit board isolated from outside is 2500V. The internal temperature sensor has a very low error at <0.6°С. The product is designed to operate in extreme environment.
| Parameter | AF | RS232 | RS485 |
|---|---|---|---|
| Standard length (L),mm | 700, 1000, 1500...up to 6000 mm | ||
| Measuring error, % | ± 0.5 % | ||
| Output signal | Analog (0…9), Frequency (500… 2000Hz). | RS232 | RS485 |
| Baud rate, bit/sec | 9600 | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | |
| Power supply (DC input voltage, V) 2500V internal isolated |
7-75 | ||
| Maximum power consumption, mA | 20 | ||
| Waterproof standard (Ingress protection rating, IP) | IP67 | ||
| Operating temperature, °C | -40...+85 | ||
| Maximum allowed humidity level,% | 100 | ||
| Resolution, bit | 12 | ||
| Digital reading range corresponding to the minimum level measurement value. | Analog (0...8V); Frequency (500...1500 Hz) | 0 | 0 |
| Digital reading range corresponding to the maximum level measurement value | Analog (1...9V); Frequency (1000...2000 Hz) | 4095 | 4095 |
| Average sampling time, (s) | 0...255 | ||
| Message interval, (s) | continuous | 1...60 | 1...60 |
| Absolute error in temperature measurement within the entire temperature measuring range, °С | ±0.6 | ||
| Average service life, (years) | 10 | ||
Installation
Selecting the location to install sensor
- Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank.
Error creating thumbnail: Unable to save thumbnail to destination
- When being installed, the sensor should not be in contact with reinforcement ribs inside the tank
Error creating thumbnail: Unable to save thumbnail to destination
Drilling the hole on fuel tank
- Drill out the central bore by bimetal core drill ø38 mm
Error creating thumbnail: Unable to save thumbnail to destination
- Drill out four mounting holes according to the diagram:
Error creating thumbnail: Unable to save thumbnail to destination
The mounting hole diameter depends on the tank material:
- ø 4 mm – for metal tank with wall thickness over 3 mm (cut M5 self screw M4.8)
Error creating thumbnail: Unable to save thumbnail to destination
- ø 7 mm – for plastic and metal tank with wall thickness up to 3 mm (for rivets)
Error creating thumbnail: Unable to save thumbnail to destination
Error creating thumbnail: Unable to save thumbnail to destination
Measuaring the tank depth and cutting sensor'measuring probe
Error creating thumbnail: Unable to save thumbnail to destination
- Cut the sensor's measuring probe so that its length is 25 mm less than the depth of the tank. Ensure that shearing line is perpendicular to the sensor longitudinal axis
Error creating thumbnail: Unable to save thumbnail to destination
Notes: Minimum allowable length of the measuring probe is 150 mm.
Configuration
On mobile platform
Connecting the sensor to LIGO mobile configurator
Error creating thumbnail: Unable to save thumbnail to destination
Configuring and managing the appropriate settings for the LiGO device sensor is essential to ensure its proper, stable, and accurate operation. It also allows for continuous monitoring of the device's operational status, potential failures (whether caused by the sensor itself or external factors), and overall lifespan.
Error creating thumbnail: Unable to save thumbnail to destination
On PC Device
Installing software and connecting configuration tool
Preparation:
- Laptop or PC
- Power supply 12 -24VDC or battery 12V
- USB to RS232 cable.
- Configuration tool from SOJI ELECTRONICS (We recommend to upgrage to the latest possible version)
Error creating thumbnail: Unable to save thumbnail to destination
12-24VDC
Download and install software. Downloading and installing softwares
Installing USB to RS232 driver
- Installing driver for USB to RS232 cable
- After finishing right click and check to ensure the driver is installed successful "Computer" >> "Manager" >> "Device Manager" >> "Port (COM & LPT)" as follow the picture bellow, otherwise, please check the cable and cable driver.
Error creating thumbnail: Unable to save thumbnail to destination
Installing sensor software configuration
- Visit our website: http://sojielectronics.com/support/download/ and download setup file "Setup Utility Program "
Error creating thumbnail: Unable to save thumbnail to destination
Parameters descriptions:
Load config: Load configurations from sensor to PC. Note: user must load configurations from sensor before changing configurations on PC.
Save config: Save configurations from PC to sensor
Update firmware: Upgrade new firmware for sensor (visit www.sojielectronics.com for the latest firmware version)
Set full: Set Full for maximum fuel level calibration
Set Empty: Set Empty for minimum fuel level calibration
Level Min: Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input.
Level Max: Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input
Output type: Selecting voltage or frequency output (used only for AF sensor)
Filter time: Setting output signal processing time (0-255). Default is 60 seconds.
Automatic transmission mode: Automatic transmission mode applied only for RS232/RS485 defines sensor output message type:
- Off – no automatic message transmission, sensor waits for tracking device request;
- HEX - automatic message transmission in binary format (used by default);
- ASCII - automatic message transmission in text format;
- ASCII EXT – automatic message transmission in extended text format. Additional Prefix and Postfix configurable parameters are available for this mode to insert required header or ending of the message.
Message interval: Time period the sensor automatically send output message to the tracking device. Parameter value range is 1…255 seconds with 1 second step. Default value is 1 second.
Actual length: The actual length of sensor probe
Address (0-254): Set the network address for the sensor. When several sensors are connected to one external device, they should have a unique network address.
Parameter selection: Selection of output value type for sensor data
One of the following output value types available for RS232 and RS485 sensor
- Fuel level in standard (normalized) units (0...1000).
- Fuel level in millimeters (mm), 0.1 mm step.
- Fuel volume in liters (L), 0.1 L step.
- Fuel volume in percentage (%), 0.4% step.
Output:
OSC frequency: Initial measuring generator frequency (Hz)
Data output: Data output (0-4095)
Sensor message: Sensor working message if sensor message is none sensor works fine, otherwise malfunction codes are displayed as table:
| Sensor message | Transcript of the malfunction Code | Possible solution |
|---|---|---|
| 255 or 254 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor |
| 253 | Short circuit in measuring probe tubes | Wash the measuring probe tubes with clean fuel, clean fuel tank of mud and water. |
| 252 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor |
| 251 | Hardware failure | Contact supplier |
| 250 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor. |
Calibration Table: This entry is used to record fuel tank calibration into the sensor internal memory. The table is filled out with the data achieved during fuel tank calibration procedure. The data is entered as a table of correspondence between measured fuel level value (Fuel level (uint) field) and fuel volume in the tank (Volume (L) field). Recommended number of table entries is 15. Max possible is 30 entries.
Enable AutoClib feature: Sensor automatically calibrates Min, Max levels after cutting. User does not need to reconfigure after cutting.
Min/Max Calibration
a) Set Empty level
- Keeping sensor apart from fuel and set Empty level
Error creating thumbnail: Unable to save thumbnail to destination
b) Set Full level
- Fill the measuring container with fuel.
- Immerse the sensor in the fuel to the full length of the measuring probe and set Full level
Error creating thumbnail: Unable to save thumbnail to destination
c) Installing screen filter
Screen filter is mounted on the measuring probe of sensor to protect measuring probe electrodes from mud and water. Using the filter extends significantly faultless lifetime of the sensor.
Screen filter mounting order: firstly put on fixator, then put on bottom stop and fix it with two side screws. Put the screen filter over bottom stop and fasten it with a fixator locks.
Error creating thumbnail: Unable to save thumbnail to destination
d) Installing and connecting
- Applying oil-and-petrol resistant non-conductive sealant to ruber gasket
Error creating thumbnail: Unable to save thumbnail to destination
- Put the sensor into the tank and fix: when fixing with rivets, use a rivet driver when bolting, put on a seal (per bolt), a spacer and a spring washer when fixing to plastic tanks with wall thickness over 3 mm, use vendor furnished self-tapping screws and a seal (per self-tapping screw)
Error creating thumbnail: Unable to save thumbnail to destination
- Connect the sensors to an external device using 7m cable
The wire cable color:
RS232/RS485:
Error creating thumbnail: Unable to save thumbnail to destination
| Wire Color | Description |
|---|---|
Black |
GND (Ground) (V-) |
Yellow |
RXD/B- |
Blue |
TXD/A+ |
Red |
12-37 VDC or 7.5-75V for SP PRO series |
AF:
Error creating thumbnail: Unable to save thumbnail to destination
| Wire Color | Description |
|---|---|
Black |
GND (Ground) (V-) |
Yellow |
Out (Analog/Frequency) |
Red |
15-37 VDC or 7.5-75V for SP PRO series |
- Connect the fuse holder to LIGO sensor power cable (brown wire) in close vicinity to the vehicle power supply circuit
- Installing the fuse in the fuse holder
e) Calibration
- Launch Sensor >> load Config >> From Sensor >> Calibration Table
Error creating thumbnail: Unable to save thumbnail to destination
- Pump fuel in the tank, the amount of pumped fuel depends on the tank's volume (at least 20 times of pumping)
- After pumping, wait for a while (about 2 minutes) for the output data to be stable, then select "add a row" and insert the actual pumped liters in "liter" box, input the data given by sensor into "Data" box. User can click on the button to sync up data, or read data in the "output" tab as the image below.
- Repeat the above steps until the oil tank is full (Attention: It is recommended to write down the information on the paper to compare with input data and avoid mistaking during the process)
- After completing the above process, select "Volume (liter) as the output data.
Error creating thumbnail: Unable to save thumbnail to destination
- Finally, click on the "Sensor" button at the top left corner -> Save config -> To sensor to save data for the sensor.
Attention:
- The time between each pumping must be at least 2 minutes apart or wait for measured values to be stable, then comes the next pumping.
f) Sealing
- Install the bolt through a hole in the seal.
Error creating thumbnail: Unable to save thumbnail to destination
Quick installation without PC
This method is only applicable to configure Min and Max level.
Preparation before setting up
- The sensor's auto-recognisation mode needs to be turned on by checking the "Enable AutoCalib Feature" box.
Error creating thumbnail: Unable to save thumbnail to destination
- External devices such as GPS tracking or Dataloger… must have the software integrated with the configurator. The configuration is performed directly on the device.
Automatically setting up and configuring the sensor after cutting
- After measuring and cutting sensor, remove iron filings and clean burrs between the tubes, then follow steps below:
Step 1: Do not allow the sensor to contact oil.
Step 2: Ensure 12-24VDC stable power supply for the sensor.
Step 3: Make sure the sensor is under stable condition within 30-60s. The sensor will automatically recognise Min and Max level.
Step 4: Cut the power and reboot. The sensor now recognizes new configurations.
Error creating thumbnail: Unable to save thumbnail to destination
Attention:
- In case of improper operation and the sensor cannot recognise properly the actual Min, Max level, user should reconfigure using a PC.
Connecting multiple sensors together
(Only applicable to RS232 and RS485)
In some situations, there are oil tanks with specific dimensions, interconnected oil tanks, or oil tanks that are either too long or too large. Using just one sensor to measure the accurate fuel level inside these oil tanks may not be feasible. Hence, there is a need to connect two or more sensors together through a data processor called SUM-DATA.
Error creating thumbnail: Unable to save thumbnail to destination
Connection diagram of the processor SUM-DATA for multiple sensors:
Error creating thumbnail: Unable to save thumbnail to destination
Error creating thumbnail: Unable to save thumbnail to destination
Operation
Troubleshooting
Maintenance
Certification / Compliance
Refer to LIGO PRO Certification & Approvals for current certificate status.