=== Notes! === | |||
* | |||
* Installation technicians should be | * LiGO SP Fuel Level Sensor measures the accurate fuel level in fuel tanks, therefore the device installation process also needs to be extremely accurate. | ||
* Installation technicians should be well-trained by specialists or experts in this field before installing the device. | |||
* Implement protection against electric shocks and electrical fires, labour safety and hygiene. | * Implement protection against electric shocks and electrical fires, labour safety and hygiene. | ||
* List of installing tools is provided in section APPENDIX A below. | |||
* List of accessories is provided in section APPENDIX B below. | |||
* List of installing tools is provided in | |||
* List of accessories is provided in | |||
== Product Overview == | == Product Overview == | ||
LIGO Fuel level sensor is produced and developed by SOJI Electronics Join Stock Company. The device is designed to measure the level of liquid fuels and other non-conductive liquids in vehicle's tanks and stationary fuel storages, applicable in different fields. The measured values will be t transformed into output signal in the form of: Analog, Frequency, RS232, RS485… and transmitted to a connected external device | |||
Under particular conditions, the device can reach a high accuracy up to 99.5%. At present, on the market there are several lines of sensor using different technologies to measure fuel level such as: magnetically operated switches (reed switches), ultrasound wave (ultrasonic sensor), capacitive sensing (capacitive sensor). Among these ones, capacitive sensing technology is considered to have highest accuracy and greatest lifespan. | |||
== Package Contents == | |||
=== Apendix B === | |||
Sensor LIGO SP and all the accessories | |||
[[File:LIGO-SP-accessories.png|center|700px|thumb|Figure 23. Sensor LIGO SP and all the accessories]] | |||
{| class="wikitable" style="text-align:center;" | |||
{| class="wikitable" | |||
|- | |- | ||
! | ! STT !! Description !! Qty | ||
|- | |- | ||
| style="text-align: | | 1 || style="text-align:left;" | LIGO Fuel Level Sensor. Standard lengths: 700, 1000, 1500mm (for other customized lengths, please contact the manufacturer) || 01 | ||
|- | |- | ||
| style="text-align: | | 2 || style="text-align:left;" | 7m cable || 01 | ||
|- | |- | ||
| style="text-align: | | 3 || style="text-align:left;" | Gasoline resistant rubber gasket || 01 | ||
|- | |- | ||
| style="text-align: | | 4 || style="text-align:left;" | Oil filter || 01 | ||
|- | |- | ||
| style="text-align: | | 5 || style="text-align:left;" | Anti-vibration spring || 01 | ||
|- | |- | ||
| style="text-align: | | 6 || style="text-align:left;" | Fuse 2A || 01 | ||
|- | |- | ||
| style="text-align: | | 7 || style="text-align:left;" | Sealing cord || 02 | ||
|- | |- | ||
| style="text-align: | | 8 || style="text-align:left;" | Rivet and screw M5x20mm || 04 | ||
|- | |- | ||
| style="text-align: | | 9 || style="text-align:left;" | Self-drilling screw M4.8x32mm || 04 | ||
|} | |} | ||
== Specifications == | == Specifications == | ||
=== LIGO-SP === | === 1. Technical specifications of the LIGO-SP product === | ||
{| class="wikitable" style="text-align:center;" | {| class="wikitable" style="text-align:center;" | ||
| Line 74: | Line 53: | ||
! Parameter !! AF !! RS232 !! RS485 | ! Parameter !! AF !! RS232 !! RS485 | ||
|- | |- | ||
| style="text-align:left;" | Standard length (L), mm || colspan="3" | 700, 1000, 1500 | | style="text-align:left;" | Standard length (L),mm || colspan="3" | 700, 1000, 1500...up to 6000 mm | ||
|- | |- | ||
| style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | | style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | ||
|- | |- | ||
| style="text-align:left;" | Output signal || Analog ( | | style="text-align:left;" | Output signal || Analog (0…9V), Frequency (500… 2000Hz). || RS232 || RS485 | ||
|- | |- | ||
| style="text-align:left;" | Baud rate, bit/sec || 9600 || colspan="2" | 2400, 4800, 9600, 19200, 38400, 57600, 115200 | | style="text-align:left;" | Baud rate, bit/sec || 9600 || colspan="2" | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | ||
|- | |- | ||
| style="text-align:left;" | Power supply (DC input voltage, V) || | | style="text-align:left;" | Power supply (DC input voltage, V) || 15-37 || 12-37 || 12-37 | ||
|- | |- | ||
| style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | | style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | ||
|- | |- | ||
| style="text-align:left;" | Ingress protection rating || colspan="3" | IP67 | | style="text-align:left;" | Waterproof standard (Ingress protection rating, IP) || colspan="3" | IP67 | ||
|- | |- | ||
| style="text-align:left;" | Operating temperature, °C || colspan="3" | | | style="text-align:left;" | Operating temperature, °C || colspan="3" | -40...+85 | ||
|- | |- | ||
| style="text-align:left;" | Maximum allowed humidity level, % || colspan="3" | 100 | | style="text-align:left;" | Maximum allowed humidity level,% || colspan="3" | 100 | ||
|- | |- | ||
| style="text-align:left;" | Resolution, bit || colspan="3" | 12 | | style="text-align:left;" | Resolution, bit || colspan="3" | 12 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range | | style="text-align:left;" | Digital reading range corresponding to the minimum level measurement value || Analog (0...8V); Frequency (500...1500 Hz) || 0 || 0 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range | | style="text-align:left;" | Digital reading range corresponding to the maximum level measurement value || Analog (1...9V); Frequency (1000...2000 Hz) || 4095 || 4095 | ||
|- | |- | ||
| style="text-align:left;" | Average sampling period, s || colspan="3" | | | style="text-align:left;" | Average sampling period, (s) || colspan="3" | 0...255 | ||
|- | |- | ||
| style="text-align:left;" | Message interval, s || Continuous || | | style="text-align:left;" | Message interval, (s) || Continuous || 1...60 || 1...60 | ||
|- | |- | ||
| style="text-align:left;" | Absolute error in temperature measurement, | | style="text-align:left;" | Absolute error in temperature measurement within the entire temperature measuring range, °С || colspan="3" | ±2 | ||
|- | |- | ||
| style="text-align:left;" | Average service life, years || colspan="3" | 8 | | style="text-align:left;" | Average service life, (years)) || colspan="3" | 8 | ||
|} | |} | ||
=== LIGO-SP | === 2. Technical specifications of the LIGO-SP PRO product === | ||
LIGO-SP | * LIGO-SP PRO product is designed for devices having wide input voltage (7-75V), the voltage of the internal sensing printed circuit board isolated from outside is 2500V. The internal temperature sensor has a very low error at <0.6°С. The product is designed to operate in extreme environment. | ||
{| class="wikitable" style="text-align:center;" | {| class="wikitable" style="text-align:center;" | ||
| Line 115: | Line 94: | ||
! Parameter !! AF !! RS232 !! RS485 | ! Parameter !! AF !! RS232 !! RS485 | ||
|- | |- | ||
| style="text-align:left;" | Standard length (L), mm || colspan="3" | 700, 1000, 1500 | | style="text-align:left;" | Standard length (L),mm || colspan="3" | 700, 1000, 1500...up to 6000 mm | ||
|- | |- | ||
| style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | | style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | ||
|- | |- | ||
| style="text-align:left;" | Output signal || Analog (0…9 | | style="text-align:left;" | Output signal || Analog (0…9), Frequency (500… 2000Hz). || RS232 || RS485 | ||
|- | |- | ||
| style="text-align:left;" | Baud rate, bit/sec || 9600 || colspan="2" | 2400, 4800, 9600, 19200, 38400, 57600, 115200 | | style="text-align:left;" | Baud rate, bit/sec || 9600 || colspan="2" | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | ||
|- | |- | ||
| style="text-align:left;" | Power supply (DC input voltage, V) || colspan="3" | | | style="text-align:left;" | Power supply (DC input voltage, V)<br>2500V internal isolated || colspan="3" | 7-75 | ||
|- | |- | ||
| style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | | style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | ||
|- | |- | ||
| style="text-align:left;" | Ingress protection rating || colspan="3" | IP67 | | style="text-align:left;" | Waterproof standard (Ingress protection rating, IP) || colspan="3" | IP67 | ||
|- | |- | ||
| style="text-align:left;" | Operating temperature, °C || colspan="3" | | | style="text-align:left;" | Operating temperature, °C || colspan="3" | -40...+85 | ||
|- | |- | ||
| style="text-align:left;" | Maximum allowed humidity level, % || colspan="3" | 100 | | style="text-align:left;" | Maximum allowed humidity level,% || colspan="3" | 100 | ||
|- | |- | ||
| style="text-align:left;" | Resolution, bit || colspan="3" | 12 | | style="text-align:left;" | Resolution, bit || colspan="3" | 12 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range | | style="text-align:left;" | Digital reading range corresponding to the minimum level measurement value. || Analog (0...8V); Frequency (500...1500 Hz) || 0 || 0 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range | | style="text-align:left;" | Digital reading range corresponding to the maximum level measurement value || Analog (1...9V); Frequency (1000...2000 Hz) || 4095 || 4095 | ||
|- | |- | ||
| style="text-align:left;" | Average sampling time, s || colspan="3" | | | style="text-align:left;" | Average sampling time, (s) || colspan="3" | 0...255 | ||
|- | |- | ||
| style="text-align:left;" | Message interval, s || | | style="text-align:left;" | Message interval, (s) || continuous || 1...60 || 1...60 | ||
|- | |- | ||
| style="text-align:left;" | Absolute error in temperature measurement, | | style="text-align:left;" | Absolute error in temperature measurement within the entire temperature measuring range, °С || colspan="3" | ±0.6 | ||
|- | |- | ||
| style="text-align:left;" | Average service life, years || colspan="3" | 10 | | style="text-align:left;" | Average service life, (years) || colspan="3" | 10 | ||
|} | |} | ||
== Installation == | == Installation == | ||
=== | === Apendix A === | ||
List of equipment for fuel level sensors installation | |||
{| class="wikitable" | {| class="wikitable" style="text-align:center;" | ||
|- | |- | ||
! | ! STT !! Descriptions !! Qty | ||
|- | |- | ||
| style="text-align: | | 1 || style="text-align:left;" | Bimetal core drill ø38 mm || 1 | ||
|- | |- | ||
| style="text-align: | | 2 || style="text-align:left;" | Core drill shank || 1 | ||
|- | |- | ||
| style="text-align: | | 3 || style="text-align:left;" | Metal drill ø7 mm & ø4 mm || 1 | ||
|- | |- | ||
| style="text-align: | | 4 || style="text-align:left;" | Hacksaw || 1 | ||
|- | |- | ||
| style="text-align: | | 5 || style="text-align:left;" | T Spanner 8mm Single Sided || 1 | ||
|- | |- | ||
| style="text-align: | | 6 || style="text-align:left;" | Tap M5 with holder || 1 | ||
|- | |- | ||
| style="text-align: | | 7 || style="text-align:left;" | Snap-seal for bolt/self-tapping screw || 1 | ||
|- | |- | ||
| style="text-align: | | 8 || style="text-align:left;" | Laptop || 1 | ||
|- | |- | ||
| style="text-align: | | 9 || style="text-align:left;" | DC power supply unit 12V-24V or battery 12V || 1 | ||
|- | |- | ||
| style="text-align: | | 10 || style="text-align:left;" | Measuring container || 1 | ||
|- | |- | ||
| style="text-align: | | 11 || style="text-align:left;" | Fuel || 1 | ||
|- | |- | ||
| style="text-align: | | 12 || style="text-align:left;" | Gauging container || 1 | ||
|- | |- | ||
| style="text-align: | | 19 || style="text-align:left;" | USB to RS232 cable || 1 | ||
|- | |- | ||
| style="text-align: | | 20 || style="text-align:left;" | Tape mesaure || 1 | ||
|} | |} | ||
=== | === V. Installation === | ||
Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank. | ==== 1. Selecting the location to install sensor ==== | ||
* Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank. | |||
[[File:LIGO-SP-fig1-location.png|center|700px|thumb|Figure 1. Selecting the location to install sensor]] | [[File:LIGO-SP-fig1-location.png|center|700px|thumb|Figure 1. Selecting the location to install sensor]] | ||
When being installed, the sensor should not be in contact with reinforcement ribs inside the tank | * When being installed, the sensor should not be in contact with reinforcement ribs inside the tank | ||
[[File:LIGO-SP-fig2-two-sensors.png|center|700px|thumb|Figure 2. Installation of two sensors in one tank allows for significant reduction]] | [[File:LIGO-SP-fig2-two-sensors.png|center|700px|thumb|Figure 2. Installation of two sensors in one tank allows for significant reduction]] | ||
=== | ==== 2. Drilling the hole on fuel tank ==== | ||
Drill out the central bore by bimetal core drill ø38 mm | * Drill out the central bore by bimetal core drill ø38 mm | ||
[[File:LIGO-SP-fig3-drilling.png|center|700px|thumb|Figure 3. Drilling the selected hole]] | [[File:LIGO-SP-fig3-drilling.png|center|700px|thumb|Figure 3. Drilling the selected hole]] | ||
Drill out four mounting holes according to the diagram: | * Drill out four mounting holes according to the diagram: | ||
[[File:LIGO-SP-fig4-mounting-holes.png|center|700px|thumb|Figure 4. Drill out four mounting holes]] | [[File:LIGO-SP-fig4-mounting-holes.png|center|700px|thumb|Figure 4. Drill out four mounting holes]] | ||
| Line 207: | Line 190: | ||
The mounting hole diameter depends on the tank material: | The mounting hole diameter depends on the tank material: | ||
* | * ø 4 mm – for metal tank with wall thickness over 3 mm (cut M5 self screw M4.8) | ||
[[File:LIGO-SP-fig5-hole-thick.png|center|700px|thumb|Figure 5.]] | [[File:LIGO-SP-fig5-hole-thick.png|center|700px|thumb|Figure 5.]] | ||
* | * ø 7 mm – for plastic and metal tank with wall thickness up to 3 mm (for rivets) | ||
[[File:LIGO-SP-fig6-rivet-nut.png|center|700px|thumb|Figure 6. Rivet nut M5]] | [[File:LIGO-SP-fig6-rivet-nut.png|center|700px|thumb|Figure 6. Rivet nut M5]] | ||
[[File:LIGO-SP-fig7-install-rivet.png|center|700px|thumb|Figure 7. Installing | [[File:LIGO-SP-fig7-install-rivet.png|center|700px|thumb|Figure 7. Installing revit nut if tank's wall is thinner than 3mm]] | ||
=== | ==== 3. Measuaring the tank depth and cutting sensor'measuring probe ==== | ||
[[File:LIGO-SP-fig8-measure-depth.png|center|700px|thumb|Figure 8. Measuring the tank depth]] | [[File:LIGO-SP-fig8-measure-depth.png|center|700px|thumb|Figure 8. Measuring the tank depth]] | ||
Cut the sensor's measuring probe so that its length is | * Cut the sensor's measuring probe so that its length is 25 mm less than the depth of the tank. Ensure that shearing line is perpendicular to the sensor longitudinal axis | ||
[[File:LIGO-SP-fig9-length.png|center|700px|thumb|Figure 9. Origin length (L) and length after cutting (Lm).]] | |||
Notes: Minimum allowable length of the measuring probe is 150 mm. | |||
== Configuration == | |||
=== VI. Installing software and connecting configuration tool === | |||
'''Preparation:''' | |||
* Laptop or PC | |||
* Power supply 12 -24VDC or battery 12V | |||
* USB to RS232 cable. | |||
* Configuration tool from SOJI ELECTRONICS (We recommend to upgrage to the latest possible version) | |||
[[File:LIGO-SP-fig10-connect.png|center|700px|thumb|Figure 10. Connecting USB to RS232 cable and configuration tool to laptop or PC]] | |||
12-24VDC | |||
=== VII. Download and install software. Downloading and installing softwares === | |||
==== 1. Installing USB to RS232 driver ==== | |||
* Installing driver for USB to RS232 cable | |||
* After finishing right click and check to ensure the driver is installed successful "Computer" >> "Manager" >> "Device Manager" >> "Port (COM & LPT)" as follow the picture bellow, otherwise, please check the cable and cable driver. | |||
[[File:LIGO-SP-fig11-driver.png|center|700px|thumb|Figure 11. Installing USB to RS232 driver successful]] | |||
==== 2. Installing sensor software configuration ==== | |||
* Visit our website: [http://sojielectronics.com/support/download/ http://sojielectronics.com/support/download/] and download setup file "Setup Utility Program " | |||
[[File:LIGO-SP-fig12-config-tool.png|center|700px|thumb|Figure 12. Sensor configuration tool]] | |||
'''Parameters descriptions:''' | |||
'''Load config:''' Load configurations from sensor to PC. Note: user must load configurations from sensor before changing configurations on PC. | |||
'''Save config:''' Save configurations from PC to sensor | |||
'''Update firmware:''' Upgrade new firmware for sensor (visit www.sojielectronics.com for the latest firmware version) | |||
'''Set full:''' Set Full for maximum fuel level calibration | |||
'''Set Empty:''' Set Empty for minimum fuel level calibration | |||
'''Level Min:''' Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input. | |||
'''Level Max:''' Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input | |||
'''Output type:''' Selecting voltage or frequency output (used only for AF sensor) | |||
'''Filter time:''' Setting output signal processing time (0-255). Default is 60 seconds. | |||
'''Automatic transmission mode:''' Automatic transmission mode applied only for RS232/RS485 defines sensor output message type: | |||
* Off – no automatic message transmission, sensor waits for tracking device request; | |||
* HEX - automatic message transmission in binary format (used by default); | |||
* ASCII - automatic message transmission in text format; | |||
* ASCII EXT – automatic message transmission in extended text format. Additional Prefix and Postfix configurable parameters are available for this mode to insert required header or ending of the message. | |||
'''Message interval:''' Time period the sensor automatically send output message to the tracking device. Parameter value range is 1…255 seconds with 1 second step. Default value is 1 second. | |||
'''Actual length:''' The actual length of sensor probe | |||
'''Address (0-254):''' Set the network address for the sensor. When several sensors are connected to one external device, they should have a unique network address. | |||
'''Parameter selection:''' Selection of output value type for sensor data | |||
One of the following output value types available for RS232 and RS485 sensor | |||
* | * Fuel level in standard (normalized) units (0...1000). | ||
* | * Fuel level in millimeters (mm), 0.1 mm step. | ||
* | * Fuel volume in liters (L), 0.1 L step. | ||
* Fuel volume in percentage (%), 0.4% step. | |||
'''Output:''' | |||
'''OSC frequency:''' Initial measuring generator frequency (Hz) | |||
''' | '''Data output:''' Data output (0-4095) | ||
'''Sensor message:''' Sensor working message if sensor message is none sensor works fine, otherwise malfunction codes are displayed as table: | |||
{| class="wikitable | {| class="wikitable" | ||
|- | |- | ||
! | ! Sensor message !! Transcript of the malfunction Code !! Possible solution | ||
|- | |- | ||
| style=" | | style="text-align:center;" | 255 or 254 || Calibration error || Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor | ||
|- | |- | ||
| style=" | | style="text-align:center;" | 253 || Short circuit in measuring probe tubes || Wash the measuring probe tubes with clean fuel, clean fuel tank of mud and water. | ||
|- | |- | ||
| style=" | | style="text-align:center;" | 252 || Calibration error || Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor | ||
|- | |- | ||
| style=" | | style="text-align:center;" | 251 || Hardware failure || Contact supplier | ||
|- | |||
| style="text-align:center;" | 250 || Calibration error || Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor. | |||
|} | |} | ||
''' | '''Calibration Table:''' This entry is used to record fuel tank calibration into the sensor internal memory. The table is filled out with the data achieved during fuel tank calibration procedure. The data is entered as a table of correspondence between measured fuel level value (Fuel level (uint) field) and fuel volume in the tank (Volume (L) field). Recommended number of table entries is 15. Max possible is 30 entries. | ||
'''Enable AutoClib feature:''' Sensor automatically calibrates Min, Max levels after cutting. User does not need to reconfigure after cutting. | |||
==== 3. Min/Max Calibration ==== | |||
'''a) Set Empty level''' | |||
* Keeping sensor apart from fuel and set Empty level | |||
[[File:LIGO-SP-fig13-set-empty.png|center|700px|thumb|Figure 13. Setting Empty level.]] | |||
| | |||
'''b) Set Full level''' | |||
* Fill the measuring container with fuel. | |||
* Immerse the sensor in the fuel to the full length of the measuring probe and set Full level | |||
[[File:LIGO-SP-fig14-set-full.png|center|700px|thumb|Figure 14. Setting Full level]] | |||
'''c) Installing screen filter''' | |||
Screen filter is mounted on the measuring probe of sensor to protect measuring probe electrodes from mud and water. Using the filter extends significantly faultless lifetime of the sensor. | |||
Screen filter mounting order: firstly put on fixator, then put on bottom stop and fix it with two side screws. Put the screen filter over bottom stop and fasten it with a fixator locks. | |||
[[File:LIGO-SP-fig15-screen-filter.png|center|700px|thumb|Figure 15. Installing screen filter procedue]] | |||
'''d) Installing and connecting''' | |||
* Applying oil-and-petrol resistant non-conductive sealant to ruber gasket | |||
[[File:LIGO-SP-fig16-sealant.png|center|700px|thumb|Figure 16. Applying the sealant to gasket]] | |||
* Put the sensor into the tank and fix: when fixing with rivets, use a rivet driver when bolting, put on a seal (per bolt), a spacer and a spring washer when fixing to plastic tanks with wall thickness over 3 mm, use vendor furnished self-tapping screws and a seal (per self-tapping screw) | |||
[[File:LIGO-SP- | [[File:LIGO-SP-fig17-install.png|center|700px|thumb|Figure 17. Put sensor into the tank]] | ||
* Connect the sensors to an external device using 7m cable | |||
The wire cable color: | |||
'''RS232/RS485:''' | |||
[[File:LIGO-SP-fig18-wiring-RS232-RS485.png|center|700px|thumb|Figure 18. Wiring diagram of RS232 and RS485 output signals]] | |||
=== | {| class="wikitable" style="text-align:center;" | ||
|- | |||
! Wire Colour !! Description | |||
|- | |||
| style="background:#1a1a1a;color:#fff;font-weight:bold;" | Black || style="text-align:left;" | GND (Ground) (V-) | |||
|- | |||
| style="background:#FFD700;color:#000;font-weight:bold;" | Yellow || style="text-align:left;" | RXD/B- | |||
|- | |||
| style="background:#1E88E5;color:#fff;font-weight:bold;" | Blue || style="text-align:left;" | TXD/A+ | |||
|- | |||
| style="background:#E53935;color:#fff;font-weight:bold;" | Red || style="text-align:left;" | 12-37 VDC or 7.5-75V for SP PRO series | |||
|} | |||
''' | '''AF:''' | ||
[[File:LIGO-SP- | [[File:LIGO-SP-fig19-wiring-AF.png|center|700px|thumb|Figure 19. Wiring diagram of Analog and Frequency output signals.]] | ||
{| class="wikitable" style="text-align:center;" | |||
|- | |||
! Wire Colour !! Description | |||
|- | |||
| style="background:#1a1a1a;color:#fff;font-weight:bold;" | Black || style="text-align:left;" | GND (Ground) (V-) | |||
|- | |||
| style="background:#FFD700;color:#000;font-weight:bold;" | Yellow || style="text-align:left;" | Out (Analog/Frequency) | |||
|- | |||
| style="background:#E53935;color:#fff;font-weight:bold;" | Red || style="text-align:left;" | 15-37 VDC or 7.5-75V for SP PRO series | |||
|} | |||
* Connect the fuse holder to LIGO sensor power cable (brown wire) in close vicinity to the vehicle power supply circuit | |||
* Installing the fuse in the fuse holder | |||
'''e) Calibration''' | |||
* Launch Sensor >> load Config >> From Sensor >> Calibration Table | |||
[[File:LIGO-SP-fig20-calib-table.png|center|700px|thumb|Figure 20. Calibration table]] | [[File:LIGO-SP-fig20-calib-table.png|center|700px|thumb|Figure 20. Calibration table]] | ||
* Pump fuel in the tank, the amount of pumped fuel depends on the tank's volume (at least 20 times of pumping) | |||
* After pumping, wait for a while (about 2 minutes) for the output data to be stable, then select "add a row" and insert the actual pumped liters in "liter" box, input the data given by sensor into "Data" box. User can click on the button to sync up data, or read data in the "output" tab as the image below. | |||
* Repeat the above steps until the oil tank is full (Attention: It is recommended to write down the information on the paper to compare with input data and avoid mistaking during the process) | |||
* After completing the above process, select "Volume (liter)'' as the output data. | |||
[[File:LIGO-SP-fig21-param.png|center|700px|thumb|Figure 21. Parameter selection]] | [[File:LIGO-SP-fig21-param.png|center|700px|thumb|Figure 21. Parameter selection]] | ||
Finally, click on the | * Finally, click on the "Sensor" button at the top left corner -> Save config -> To sensor to save data for the sensor. | ||
'''Attention:''' | |||
* The time between each pumping must be at least 2 minutes apart or wait for measured values to be stable, then comes the next pumping. | |||
'''f) Sealing''' | |||
* Install the bolt through a hole in the seal. | |||
[[File:LIGO-SP-fig22-sealing.png|center|700px|thumb|Figure 22. Sealing]] | |||
=== Quick installation without PC === | |||
This method is only applicable to configure Min and Max level. | |||
==== I. Preparation before setting up ==== | |||
' | * The sensor's auto-recognisation mode needs to be turned on by checking the "Enable AutoCalib Feature" box. | ||
[[File:LIGO-SP-fig24-autocalib.png|center|700px|thumb|Figure 24. Turning on the auto-recognisation mode before installing]] | |||
* External devices such as GPS tracking or Dataloger… must have the software integrated with the configurator. The configuration is performed directly on the device. | |||
==== II. Automatically setting up and configuring the sensor after cutting ==== | |||
* After measuring and cutting sensor, remove iron filings and clean burrs between the tubes, then follow steps below: | |||
'''Step 1:''' Do not allow the sensor to contact oil. | |||
'''Step 2:''' Ensure 12-24VDC stable power supply for the sensor. | |||
'''Step 3:''' Make sure the sensor is under stable condition within 30-60s. The sensor will automatically recognise Min and Max level. | |||
'''Step 4:''' Cut the power and reboot. The sensor now recognizes new configurations. | |||
[[File:LIGO-SP-fig25-auto-config.png|center|700px|thumb|Figure 25. Leave the sensor in the air, provide with a stable power supply in 30-60s to configure "Min" level.]] | |||
'''Attention:''' | |||
- In case of improper operation and the sensor cannot recognise properly the actual Min, Max level, user should reconfigure using a PC. | |||
== Operation == | |||
== Troubleshooting == | |||
== Maintenance == | == Maintenance == | ||
=== | === Attention! === | ||
* The manufacturer is not responsible for product availability in case of non-compliance of requirements of this service manual, unauthorized service and repair; if device has damage or traces of opening of head's body, mechanical damage of the probe or the interface cable, as well as traces of corrosive acids, open flame, high voltage, lightning strikes or other natural factors. | |||
== Certification / Compliance == | == Certification / Compliance == | ||
Refer to [[Product Certification & Approvals]] for current certificate status.'' | |||
== Support / Contact == | == Support / Contact == | ||
Revision as of 04:17, 11 June 2026
Safety Information
Notes!
- LiGO SP Fuel Level Sensor measures the accurate fuel level in fuel tanks, therefore the device installation process also needs to be extremely accurate.
- Installation technicians should be well-trained by specialists or experts in this field before installing the device.
- Implement protection against electric shocks and electrical fires, labour safety and hygiene.
- List of installing tools is provided in section APPENDIX A below.
- List of accessories is provided in section APPENDIX B below.
Product Overview
LIGO Fuel level sensor is produced and developed by SOJI Electronics Join Stock Company. The device is designed to measure the level of liquid fuels and other non-conductive liquids in vehicle's tanks and stationary fuel storages, applicable in different fields. The measured values will be t transformed into output signal in the form of: Analog, Frequency, RS232, RS485… and transmitted to a connected external device
Under particular conditions, the device can reach a high accuracy up to 99.5%. At present, on the market there are several lines of sensor using different technologies to measure fuel level such as: magnetically operated switches (reed switches), ultrasound wave (ultrasonic sensor), capacitive sensing (capacitive sensor). Among these ones, capacitive sensing technology is considered to have highest accuracy and greatest lifespan.
Package Contents
Apendix B
Sensor LIGO SP and all the accessories

| STT | Description | Qty |
|---|---|---|
| 1 | LIGO Fuel Level Sensor. Standard lengths: 700, 1000, 1500mm (for other customized lengths, please contact the manufacturer) | 01 |
| 2 | 7m cable | 01 |
| 3 | Gasoline resistant rubber gasket | 01 |
| 4 | Oil filter | 01 |
| 5 | Anti-vibration spring | 01 |
| 6 | Fuse 2A | 01 |
| 7 | Sealing cord | 02 |
| 8 | Rivet and screw M5x20mm | 04 |
| 9 | Self-drilling screw M4.8x32mm | 04 |
Specifications
1. Technical specifications of the LIGO-SP product
| Parameter | AF | RS232 | RS485 |
|---|---|---|---|
| Standard length (L),mm | 700, 1000, 1500...up to 6000 mm | ||
| Measuring error, % | ± 0.5 % | ||
| Output signal | Analog (0…9V), Frequency (500… 2000Hz). | RS232 | RS485 |
| Baud rate, bit/sec | 9600 | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | |
| Power supply (DC input voltage, V) | 15-37 | 12-37 | 12-37 |
| Maximum power consumption, mA | 20 | ||
| Waterproof standard (Ingress protection rating, IP) | IP67 | ||
| Operating temperature, °C | -40...+85 | ||
| Maximum allowed humidity level,% | 100 | ||
| Resolution, bit | 12 | ||
| Digital reading range corresponding to the minimum level measurement value | Analog (0...8V); Frequency (500...1500 Hz) | 0 | 0 |
| Digital reading range corresponding to the maximum level measurement value | Analog (1...9V); Frequency (1000...2000 Hz) | 4095 | 4095 |
| Average sampling period, (s) | 0...255 | ||
| Message interval, (s) | Continuous | 1...60 | 1...60 |
| Absolute error in temperature measurement within the entire temperature measuring range, °С | ±2 | ||
| Average service life, (years)) | 8 | ||
2. Technical specifications of the LIGO-SP PRO product
- LIGO-SP PRO product is designed for devices having wide input voltage (7-75V), the voltage of the internal sensing printed circuit board isolated from outside is 2500V. The internal temperature sensor has a very low error at <0.6°С. The product is designed to operate in extreme environment.
| Parameter | AF | RS232 | RS485 |
|---|---|---|---|
| Standard length (L),mm | 700, 1000, 1500...up to 6000 mm | ||
| Measuring error, % | ± 0.5 % | ||
| Output signal | Analog (0…9), Frequency (500… 2000Hz). | RS232 | RS485 |
| Baud rate, bit/sec | 9600 | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | |
| Power supply (DC input voltage, V) 2500V internal isolated |
7-75 | ||
| Maximum power consumption, mA | 20 | ||
| Waterproof standard (Ingress protection rating, IP) | IP67 | ||
| Operating temperature, °C | -40...+85 | ||
| Maximum allowed humidity level,% | 100 | ||
| Resolution, bit | 12 | ||
| Digital reading range corresponding to the minimum level measurement value. | Analog (0...8V); Frequency (500...1500 Hz) | 0 | 0 |
| Digital reading range corresponding to the maximum level measurement value | Analog (1...9V); Frequency (1000...2000 Hz) | 4095 | 4095 |
| Average sampling time, (s) | 0...255 | ||
| Message interval, (s) | continuous | 1...60 | 1...60 |
| Absolute error in temperature measurement within the entire temperature measuring range, °С | ±0.6 | ||
| Average service life, (years) | 10 | ||
Installation
Apendix A
List of equipment for fuel level sensors installation
| STT | Descriptions | Qty |
|---|---|---|
| 1 | Bimetal core drill ø38 mm | 1 |
| 2 | Core drill shank | 1 |
| 3 | Metal drill ø7 mm & ø4 mm | 1 |
| 4 | Hacksaw | 1 |
| 5 | T Spanner 8mm Single Sided | 1 |
| 6 | Tap M5 with holder | 1 |
| 7 | Snap-seal for bolt/self-tapping screw | 1 |
| 8 | Laptop | 1 |
| 9 | DC power supply unit 12V-24V or battery 12V | 1 |
| 10 | Measuring container | 1 |
| 11 | Fuel | 1 |
| 12 | Gauging container | 1 |
| 19 | USB to RS232 cable | 1 |
| 20 | Tape mesaure | 1 |
V. Installation
1. Selecting the location to install sensor
- Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank.

- When being installed, the sensor should not be in contact with reinforcement ribs inside the tank

2. Drilling the hole on fuel tank
- Drill out the central bore by bimetal core drill ø38 mm

- Drill out four mounting holes according to the diagram:

The mounting hole diameter depends on the tank material:
- ø 4 mm – for metal tank with wall thickness over 3 mm (cut M5 self screw M4.8)

- ø 7 mm – for plastic and metal tank with wall thickness up to 3 mm (for rivets)


3. Measuaring the tank depth and cutting sensor'measuring probe

- Cut the sensor's measuring probe so that its length is 25 mm less than the depth of the tank. Ensure that shearing line is perpendicular to the sensor longitudinal axis

Notes: Minimum allowable length of the measuring probe is 150 mm.
Configuration
VI. Installing software and connecting configuration tool
Preparation:
- Laptop or PC
- Power supply 12 -24VDC or battery 12V
- USB to RS232 cable.
- Configuration tool from SOJI ELECTRONICS (We recommend to upgrage to the latest possible version)

12-24VDC
VII. Download and install software. Downloading and installing softwares
1. Installing USB to RS232 driver
- Installing driver for USB to RS232 cable
- After finishing right click and check to ensure the driver is installed successful "Computer" >> "Manager" >> "Device Manager" >> "Port (COM & LPT)" as follow the picture bellow, otherwise, please check the cable and cable driver.

2. Installing sensor software configuration
- Visit our website: http://sojielectronics.com/support/download/ and download setup file "Setup Utility Program "

Parameters descriptions:
Load config: Load configurations from sensor to PC. Note: user must load configurations from sensor before changing configurations on PC.
Save config: Save configurations from PC to sensor
Update firmware: Upgrade new firmware for sensor (visit www.sojielectronics.com for the latest firmware version)
Set full: Set Full for maximum fuel level calibration
Set Empty: Set Empty for minimum fuel level calibration
Level Min: Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input.
Level Max: Configure LIGO SP-AF output voltage or frequency range according to the voltage or frequency range of the tracking device input
Output type: Selecting voltage or frequency output (used only for AF sensor)
Filter time: Setting output signal processing time (0-255). Default is 60 seconds.
Automatic transmission mode: Automatic transmission mode applied only for RS232/RS485 defines sensor output message type:
- Off – no automatic message transmission, sensor waits for tracking device request;
- HEX - automatic message transmission in binary format (used by default);
- ASCII - automatic message transmission in text format;
- ASCII EXT – automatic message transmission in extended text format. Additional Prefix and Postfix configurable parameters are available for this mode to insert required header or ending of the message.
Message interval: Time period the sensor automatically send output message to the tracking device. Parameter value range is 1…255 seconds with 1 second step. Default value is 1 second.
Actual length: The actual length of sensor probe
Address (0-254): Set the network address for the sensor. When several sensors are connected to one external device, they should have a unique network address.
Parameter selection: Selection of output value type for sensor data
One of the following output value types available for RS232 and RS485 sensor
- Fuel level in standard (normalized) units (0...1000).
- Fuel level in millimeters (mm), 0.1 mm step.
- Fuel volume in liters (L), 0.1 L step.
- Fuel volume in percentage (%), 0.4% step.
Output:
OSC frequency: Initial measuring generator frequency (Hz)
Data output: Data output (0-4095)
Sensor message: Sensor working message if sensor message is none sensor works fine, otherwise malfunction codes are displayed as table:
| Sensor message | Transcript of the malfunction Code | Possible solution |
|---|---|---|
| 255 or 254 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor |
| 253 | Short circuit in measuring probe tubes | Wash the measuring probe tubes with clean fuel, clean fuel tank of mud and water. |
| 252 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor |
| 251 | Hardware failure | Contact supplier |
| 250 | Calibration error | Check if the measuring probe actual size value is inserted correctly and (or) re-calibrate the sensor. |
Calibration Table: This entry is used to record fuel tank calibration into the sensor internal memory. The table is filled out with the data achieved during fuel tank calibration procedure. The data is entered as a table of correspondence between measured fuel level value (Fuel level (uint) field) and fuel volume in the tank (Volume (L) field). Recommended number of table entries is 15. Max possible is 30 entries.
Enable AutoClib feature: Sensor automatically calibrates Min, Max levels after cutting. User does not need to reconfigure after cutting.
3. Min/Max Calibration
a) Set Empty level
- Keeping sensor apart from fuel and set Empty level

b) Set Full level
- Fill the measuring container with fuel.
- Immerse the sensor in the fuel to the full length of the measuring probe and set Full level

c) Installing screen filter
Screen filter is mounted on the measuring probe of sensor to protect measuring probe electrodes from mud and water. Using the filter extends significantly faultless lifetime of the sensor.
Screen filter mounting order: firstly put on fixator, then put on bottom stop and fix it with two side screws. Put the screen filter over bottom stop and fasten it with a fixator locks.

d) Installing and connecting
- Applying oil-and-petrol resistant non-conductive sealant to ruber gasket

- Put the sensor into the tank and fix: when fixing with rivets, use a rivet driver when bolting, put on a seal (per bolt), a spacer and a spring washer when fixing to plastic tanks with wall thickness over 3 mm, use vendor furnished self-tapping screws and a seal (per self-tapping screw)

- Connect the sensors to an external device using 7m cable
The wire cable color:
RS232/RS485:

| Wire Colour | Description |
|---|---|
| Black | GND (Ground) (V-) |
| Yellow | RXD/B- |
| Blue | TXD/A+ |
| Red | 12-37 VDC or 7.5-75V for SP PRO series |
AF:

| Wire Colour | Description |
|---|---|
| Black | GND (Ground) (V-) |
| Yellow | Out (Analog/Frequency) |
| Red | 15-37 VDC or 7.5-75V for SP PRO series |
- Connect the fuse holder to LIGO sensor power cable (brown wire) in close vicinity to the vehicle power supply circuit
- Installing the fuse in the fuse holder
e) Calibration
- Launch Sensor >> load Config >> From Sensor >> Calibration Table

- Pump fuel in the tank, the amount of pumped fuel depends on the tank's volume (at least 20 times of pumping)
- After pumping, wait for a while (about 2 minutes) for the output data to be stable, then select "add a row" and insert the actual pumped liters in "liter" box, input the data given by sensor into "Data" box. User can click on the button to sync up data, or read data in the "output" tab as the image below.
- Repeat the above steps until the oil tank is full (Attention: It is recommended to write down the information on the paper to compare with input data and avoid mistaking during the process)
- After completing the above process, select "Volume (liter) as the output data.

- Finally, click on the "Sensor" button at the top left corner -> Save config -> To sensor to save data for the sensor.
Attention:
- The time between each pumping must be at least 2 minutes apart or wait for measured values to be stable, then comes the next pumping.
f) Sealing
- Install the bolt through a hole in the seal.

Quick installation without PC
This method is only applicable to configure Min and Max level.
I. Preparation before setting up
- The sensor's auto-recognisation mode needs to be turned on by checking the "Enable AutoCalib Feature" box.

- External devices such as GPS tracking or Dataloger… must have the software integrated with the configurator. The configuration is performed directly on the device.
II. Automatically setting up and configuring the sensor after cutting
- After measuring and cutting sensor, remove iron filings and clean burrs between the tubes, then follow steps below:
Step 1: Do not allow the sensor to contact oil.
Step 2: Ensure 12-24VDC stable power supply for the sensor.
Step 3: Make sure the sensor is under stable condition within 30-60s. The sensor will automatically recognise Min and Max level.
Step 4: Cut the power and reboot. The sensor now recognizes new configurations.

Attention:
- In case of improper operation and the sensor cannot recognise properly the actual Min, Max level, user should reconfigure using a PC.
Operation
Troubleshooting
Maintenance
Attention!
- The manufacturer is not responsible for product availability in case of non-compliance of requirements of this service manual, unauthorized service and repair; if device has damage or traces of opening of head's body, mechanical damage of the probe or the interface cable, as well as traces of corrosive acids, open flame, high voltage, lightning strikes or other natural factors.
Certification / Compliance
Refer to Product Certification & Approvals for current certificate status.
Support / Contact
| Channel | Detail |
|---|---|
| Company | SOJI ELECTRONICS.,JSC |
| Address | C50-LK13, Lot No. 09, New Urban Area, Le Trong Tan street, Duong Noi Ward, Ha Dong District, Hanoi City, Vietnam |
| Tel/Fax | +84 24 62 932 369 |
| contact@sojielectronics.com | |
| Website | sojielectronics.com |
Revision History
Loading revision history...