LIGO PRO BLE User Guide: Difference between revisions
| [checked revision] | [checked revision] |
| Line 42: | Line 42: | ||
== Specifications == | == Specifications == | ||
{| class="wikitable" style="text-align:center;" | {| class="wikitable" style="text-align:center;" | ||
| Line 49: | Line 47: | ||
! Parameter !! AF !! RS232 !! RS485 | ! Parameter !! AF !! RS232 !! RS485 | ||
|- | |- | ||
| style="text-align:left;" | Standard length (L),mm || colspan="3" | 700, 1000, 1500...up to 6000 mm | | style="text-align:left;" | Standard length (L), mm || colspan="3" | 700, 1000, 1500...up to 6000 mm | ||
|- | |- | ||
| style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | | style="text-align:left;" | Measuring error, % || colspan="3" | ± 0.5 % | ||
|- | |- | ||
| style="text-align:left;" | Output signal || Analog ( | | style="text-align:left;" | Output signal || Analog (0-9V) || RS232 || RS485 | ||
|- | |- | ||
| style="text-align:left;" | Baud rate, bit/sec || colspan="3" | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | | style="text-align:left;" | Baud rate, bit/sec || colspan="3" | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | ||
|- | |- | ||
| style="text-align:left;" | Power supply (DC input voltage, V) || colspan="3" | 6- | | style="text-align:left;" | Power supply (DC input voltage, V) || colspan="3" | 6-40V | ||
|- | |- | ||
| style="text-align: left;" |Supply protection (Over-voltage 100 VDC for 2 minutes. Reverse polarity) | | style="text-align:left;" | Supply protection (Over-voltage 100 VDC for 2 minutes. Reverse polarity) || colspan="3" | Yes | ||
| colspan="3" |Yes | |||
|- | |- | ||
| style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | | style="text-align:left;" | Maximum power consumption, mA || colspan="3" | 20 | ||
| Line 72: | Line 69: | ||
| style="text-align:left;" | Resolution, bit || colspan="3" | 12 | | style="text-align:left;" | Resolution, bit || colspan="3" | 12 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range corresponding to the minimum level measurement value || Analog ( | | style="text-align:left;" | Digital reading range corresponding to the minimum level measurement value || Analog (0...8V) || 0 || 0 | ||
|- | |- | ||
| style="text-align:left;" | Digital reading range corresponding to the maximum level measurement value || Analog ( | | style="text-align:left;" | Digital reading range corresponding to the maximum level measurement value || Analog (1...9V) || 4095 || 4095 | ||
|- | |- | ||
| style="text-align:left;" | Average sampling period, | | style="text-align:left;" | Average sampling period, s || colspan="3" | 0...255 | ||
|- | |- | ||
| style="text-align:left;" | Message interval, | | style="text-align:left;" | Message interval, s || Continuous || 1...255 || 1...255 | ||
|- | |- | ||
| style="text-align:left;" | Absolute error in temperature measurement within the entire temperature measuring range, °С || colspan="3" | ±1 | | style="text-align:left;" | Absolute error in temperature measurement within the entire temperature measuring range, °С || colspan="3" | ±1 | ||
|- | |- | ||
| style="text-align:left;" | | | style="text-align:left;" | Bluetooth specs || colspan="3" | Bluetooth 5.1, IEEE 802.15.4-2006, 2.4 GHz, -95 dBm sensitivity, +8 dBm TX Power | ||
|- | |- | ||
| style="text-align: left;" | | | style="text-align:left;" | Average service life, years (expected) || 10 || 10 || 10 | ||
| | |||
|} | |} | ||
Revision as of 08:39, 22 June 2026
Safety Information
| ℹ️ NOTICE — Installer Qualifications and Safety |
|---|
|
Product Overview
LIGO PRO BLE sensor is produced and developed by SOJI Electronics Join Stock Company. The device is designed to measure the level of liquid fuels and other non-conductive liquids in vehicle's tanks and stationary fuel storages, applicable in different fields. The measured values will be t transformed into output signal in the form of: Analog, Frequency, RS232, RS485… and transmitted to a connected external device
Under particular conditions, the device can reach a high accuracy up to 99.5%. At present, on the market there are several lines of sensor using different technologies to measure fuel level such as: magnetically operated switches (reed switches), ultrasound wave (ultrasonic sensor), capacitive sensing (capacitive sensor). Among these ones, capacitive sensing technology is considered to have highest accuracy and greatest lifespan.
Package Contents
Sensor LIGO PRO BLE and all the accessories
| STT | Description | Qty |
|---|---|---|
| 1 | LIGO PRO BLE sensor. Standard lengths: 700, 1000, 1500mm (for other customized lengths, please contact the manufacturer) | 01 |
| 2 | 7m cable | 01 |
| 3 | Gasoline resistant rubber gasket | 01 |
| 4 | Oil filter | 01 |
| 5 | Anti-vibration spring | 01 |
| 6 | Fuse 1A | 01 |
| 7 | Sealing cord | 02 |
| 8 | Rivet and screw M5x20mm | 04 |
| 9 | Self-drilling screw M4.8x32mm | 04 |
Specifications
| Parameter | AF | RS232 | RS485 |
|---|---|---|---|
| Standard length (L), mm | 700, 1000, 1500...up to 6000 mm | ||
| Measuring error, % | ± 0.5 % | ||
| Output signal | Analog (0-9V) | RS232 | RS485 |
| Baud rate, bit/sec | 2400, 4800, 9600, 19200, 38400, 57600, 115200. | ||
| Power supply (DC input voltage, V) | 6-40V | ||
| Supply protection (Over-voltage 100 VDC for 2 minutes. Reverse polarity) | Yes | ||
| Maximum power consumption, mA | 20 | ||
| Waterproof standard (Ingress protection rating, IP) | IP69K | ||
| Operating temperature, °C | -40...+85 | ||
| Maximum allowed humidity level,% | 100 | ||
| Resolution, bit | 12 | ||
| Digital reading range corresponding to the minimum level measurement value | Analog (0...8V) | 0 | 0 |
| Digital reading range corresponding to the maximum level measurement value | Analog (1...9V) | 4095 | 4095 |
| Average sampling period, s | 0...255 | ||
| Message interval, s | Continuous | 1...255 | 1...255 |
| Absolute error in temperature measurement within the entire temperature measuring range, °С | ±1 | ||
| Bluetooth specs | Bluetooth 5.1, IEEE 802.15.4-2006, 2.4 GHz, -95 dBm sensitivity, +8 dBm TX Power | ||
| Average service life, years (expected) | 10 | 10 | 10 |
Installation
Apendix A
List of equipment for fuel level sensors installation
| STT | Descriptions | Qty |
|---|---|---|
| 1 | Bimetal core drill ø38 mm | 1 |
| 2 | Core drill shank | 1 |
| 3 | Metal drill ø7 mm & ø4 mm | 1 |
| 4 | Hacksaw | 1 |
| 5 | T Spanner 8mm Single Sided | 1 |
| 6 | Tap M5 with holder | 1 |
| 7 | Snap-seal for bolt/self-tapping screw | 1 |
| 8 | Mobile phone | 1 |
| 9 | DC power supply unit 12V-24V or battery 12V | 1 |
| 10 | Measuring container | 1 |
| 11 | Fuel | 1 |
| 12 | Gauging container | 1 |
| 20 | Tape mesaure | 1 |
Installation
Selecting the location to install sensor
- Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank.
Error creating thumbnail: Unable to save thumbnail to destination
- When being installed, the sensor should not be in contact with reinforcement ribs inside the tank
Error creating thumbnail: Unable to save thumbnail to destination
Drilling the hole on fuel tank
- Drill out the central bore by bimetal core drill ø38 mm
Error creating thumbnail: Unable to save thumbnail to destination
- Drill out four mounting holes according to the diagram:
Error creating thumbnail: Unable to save thumbnail to destination
The mounting hole diameter depends on the tank material:
- ø 4 mm – for metal tank with wall thickness over 3 mm (cut M5 self screw M4.8)
Error creating thumbnail: Unable to save thumbnail to destination
- ø 7 mm – for plastic and metal tank with wall thickness up to 3 mm (for rivets)
Error creating thumbnail: Unable to save thumbnail to destination
Error creating thumbnail: Unable to save thumbnail to destination
Measuaring the tank depth and cutting sensor'measuring probe
Error creating thumbnail: Unable to save thumbnail to destination
- Cut the sensor's measuring probe so that its length is 25 mm less than the depth of the tank. Ensure that shearing line is perpendicular to the sensor longitudinal axis
Error creating thumbnail: Unable to save thumbnail to destination
Notes: Minimum allowable length of the measuring probe is 150 mm.
Installing screen filter
Screen filter is mounted on the measuring probe of sensor to protect measuring probe electrodes from mud and water. Using the filter extends significantly faultless lifetime of the sensor.
Screen filter mounting order: firstly put on fixator, then put on bottom stop and fix it with two side screws. Put the screen filter over bottom stop and fasten it with a fixator locks.
Error creating thumbnail: Unable to save thumbnail to destination
Installing and connecting
- Applying oil-and-petrol resistant non-conductive sealant to ruber gasket
Error creating thumbnail: Unable to save thumbnail to destination
- Put the sensor into the tank and fix: when fixing with rivets, use a rivet driver when bolting, put on a seal (per bolt), a spacer and a spring washer when fixing to plastic tanks with wall thickness over 3 mm, use vendor furnished self-tapping screws and a seal (per self-tapping screw)
Error creating thumbnail: Unable to save thumbnail to destination
- Connect the sensors to an external device using 7m cable
The wire cable color:
RS232/RS485:
Error creating thumbnail: Unable to save thumbnail to destination
| Wire Color | Description |
|---|---|
Black |
GND (Ground) (V-) |
Yellow |
RXD/B- |
Blue |
TXD/A+ |
Red |
12-37 VDC or 7.5-75V for SP PRO series |
AF:
Error creating thumbnail: Unable to save thumbnail to destination
| Wire Color | Description |
|---|---|
Black |
GND (Ground) (V-) |
Yellow |
Out (Analog/Frequency) |
Red |
15-37 VDC or 7.5-75V for SP PRO series |
- Connect the fuse holder to LIGO sensor power cable (brown wire) in close vicinity to the vehicle power supply circuit
- Installing the fuse in the fuse holder
Sealing
- Install the bolt through a hole in the seal.
Error creating thumbnail: Unable to save thumbnail to destination
Configuration
Connecting sensor to smartphone and setting
To configure the LIGO AIR fuel sensor, download the LIGO BLE Configurator app on Appstore (for IOS) or CH Play (for Android devices).
Hereinafter LIGO BLE Configurator is referred to as the "application" or "app".
Note: For full operation, you must grant all the permissions requested by the app
-
Figure 16. Grant all the permissions request by program
-
Figure 17. Grant all the permissions request by program
Grant all the permissions request by program as above
Connecting sensor
Run the application and select the sensor you want to connect to, as shown in the pictures below:
-
Figure 18. Selecting sensor type
-
Figure 19. Connecting sensor
Set Empty and Set Full
Step 1: Set Full
- Immerse the sensor in fuel until the fuel reaches the sensor flange
- Wait for C_working value to stablize and then press Set Full button
Error creating thumbnail: Unable to save thumbnail to destination
Step 2: Set Empty
- Remove the sensor from the fuel and wait for 1-2 minutes allow the fuel drain from the measuring probe and then press Set Empty button.
Calibration table
After installation, the sensor must be calibrated to ensure accurate volume measurement. Calibration table can be performed either on the platform (server) or locally on the sensor.
- Calibration table on the Platform (Server): The sensor sends raw level values (ranging from 0 to 4095) to the server via the telematic device. The platform uses a calibration table to convert these values into volume (liters).
- Calibration table on the Sensor: The sensor directly sends volume values (liters) based on the internal calibration table.
Note: For LIGO AIR sensors, the manufacturer recommends performing calibration table on the platform.
Operation
Troubleshooting
Maintenance
Attention!
- The manufacturer is not responsible for product availability in case of non-compliance of requirements of this service manual, unauthorized service and repair; if device has damage or traces of opening of head's body, mechanical damage of the probe or the interface cable, as well as traces of corrosive acids, open flame, high voltage, lightning strikes or other natural factors.
Certification / Compliance
Refer to LIGO PRO BLE Certification & Approvals for current certificate status.
Support / Contact
| Channel | Detail |
|---|---|
| Company | SOJI ELECTRONICS.,JSC |
| Address | C50-LK13, Lot No. 09, New Urban Area, Le Trong Tan street, Duong Noi Ward, Ha Dong District, Hanoi City, Vietnam |
| Tel/Fax | +84 24 62 932 369 |
| contact@sojielectronics.com | |
| Website | sojielectronics.com |
Revision History